FAQ-How to collect dump on PON port of MA5600T by tftp

Publication Date:  2012-07-25 Views:  56 Downloads:  0
Issue Description

Q;
for troubleshooting of the packets transfered between OLT and ONT problems, it is useful to analyze the traffic dump.
ONT
Equipment-ID : Any type

OLT
Equipment-ID : SmartAX MA5600T
Main Software Version : V800R006C02

Alarm Information


Null

Handling Process


A:
Need to follow steps:

MA5680T(config)#acl 4000

// create the ACL

MA5680T(config-acl-link-4000)#rule 1 permit

MA5680T(config)#diag

MA5680T(diagnose)#su

// enter su mode

MA5680T(su)%%backup-server debug primary 80.73.64.23 tftp

// tftp server ip , for example: 80.73.64.23

MA5680T(su)%%capture item 1 inbound link-group 4000 rule 1 port 0/1/3

// direction can be: inbound / outboun / bidirection

// PON port, for example: 0/0/0

MA5680T(su)%%capture start -c 1000

// count of collected packets, for example: 1000, in attach such case

// If set count of packets more then need, capturing can be stop by command:

MA5680T(su)%%capture stop

Root Cause


Null

Suggestions


Null

END