SLQ4 card version compatibility

Publication Date:  2012-07-25 Views:  66 Downloads:  0
Issue Description
Many services down when added new SLQ4 board in OSN 3500, after that board deleted & services again provisioned to restore for the same.
Alarm Information
Some AU_AIS, R_LOS reported. As the services were working on the 4&5 ports of 14-N1SLT1 board. We found there was R-LOS alarms reported on these channels at that time
Handling Process
If the same kind of problem persists, like by adding any new board if some services affect then first we need to check the slot & version compatibility.
Root Cause
Check the version for the GSCC board and SLQ4 board:
:ver;
BIOS        08.09.46T02 20060521 18:25:29 inactive
ExtBios     09.09.46T02 20060810 11:58:38 active
NeSoft(D)   5.21.16.13 20070416 14:15:18
Platform(T) 5.00.07.C03T13 20070328 22:13:59
AosSoft(T)  5.99.02.10T26 20070228 09:35:38
Logic       (U1004)130
Dsp      
:cfg-get-bdverinfo:1;
    BOARD-VER-INFO
PCB      Version : SSN4SLQ41 VER.A
BIOS     Version : 2.63
ExtBIOS  Version : 2.63
Software Version : 8.13
Logic    Version : (U8)100  
From the Hardware Description document (SE0000249602) of R6 version, we know the SLQ4 board can not be added at slot 15 on R6 version. So, it is a risk when they are running together. 
Suggestions
For adding new board in to any equipment, first we need to check the slot & version compatibility & then insert. 

END