No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-Why is Laser forced to open automatically

Publication Date:  2012-07-25 Views:  35 Downloads:  0
Issue Description
After upgraded 6800 from the version of V1R4C02B01j to V1R4C04SPC800, OTU board reported LSR_FORCE_OPEN alarm.
Alarm Information
LSR_FORCE_OPEN
Handling Process
We could ignore this alarm temporarily when upgrading. We also could close the status if necessary.
Root Cause
Channel use status was unused and laser status was close before upgrade. OTU board was resetted because of upgrade. Then laser status information was initialized and became the default setting which 
means the changed from close to open. At the same time, the alarm of LSR_FORCE_OPEN was generated in the OTU when the status was unused and open. Furthermore, laser status information cannot be 
saved into the database of SCC card. Once OTU is resetted, it will re-configurated according to its own program and that is the default setting I mentioned. 
Suggestions
 

END