No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

The IMS subscriber call is failed when Rf version is R7 and time stamp type is STR

Publication Date:  2012-08-06 Views:  42 Downloads:  0
Issue Description

IMS version is IMS8.1, CCF version is V300R002C68SPC200, ATS version is V100R003C01SPC100.
When IMS subscriber makes a call, the call is failed and CCF returns LIA with the cause value "diameter-invalid-value".

Alarm Information

NULL

Handling Process

Change the time stamp type of RFPARAM to “INT” via MML command "MOD RFPARAM" on ATS client.
 

Root Cause

When the Rf version in ATS is R7, the time stamp type must not be “STR”.



Suggestions

NULL
 

END