FAQ-How can we configure the DCC pass-through

Publication Date:  2012-07-25 Views:  37 Downloads:  0
Issue Description

Customer need optimise the ECC subnet, and want to know how can we configure the DCC pass-through at the intersect NEs.



 


Alarm Information

Null


Handling Process

1. Delete the auto DCC configuration on the boards which should provide the DCC pass through channels.


For NG-SDH:

:cm-del-ohpchan:2,1,D1-D3

:cm-del-ohpchan:2,2,D1-D3

For Metro 3000:

:ecc-set-fiberport:2,1,disable,D1-D3

:ecc-set-fiberport:2,2,disable,D1-D3

2. Add the pass through DCC channels.

For NG-SDH:

:cm-add-dccphy:2,1,D1,2,2,D1

:cm-add-dccphy:2,1,D2,2,2,D2

:cm-add-dccphy:2,1,D3,2,2,D3

For Metro 3000:

:ecc-set-fiberport:2,1,disable,D1-D3

:ecc-set-fiberport:2,2,disable,D1-D3

:cm-set-dccphy:2,1,D1,2,2,D1,add

:cm-set-dccphy:2,1,D2,2,2,D2,add

:cm-set-dccphy:2,1,D3,2,2,D3,add


Root Cause

Null


Suggestions

If there are too many NEs in the same ECC subnet, it will cause the ECC storm.

The recommend NE quantity in one ECC subnet should be no more than 60.