Clock view in U2000 does not show links between nodes

Publication Date:  2012-07-25 Views:  38 Downloads:  0
Issue Description


The clock priorities have been configured properly in each NE but the clock view does not show the link status



 iew only shows


Alarm Information


N/A


Handling Process


Go to VIEW menu / Display Settings / Legend and The legend view is comming out.



Click in Filter and thick "link Level"







 


Root Cause


When an U2000 Client is installed, the Link levels are disabled by default and it doesn't show the Clock Links even if they are working Properly




Suggestions


Once the U2000 Is installed, try to thick all the functions in the legend.

END