FAQ How enable E1 DCN parameters by navigator commands

Publication Date:  2012-07-25 Views:  44 Downloads:  0
Issue Description

In RTN910V1R1 Huawei engineer needed to enable E1 DCN parameters for the transportation management, because RTN disable the port used by it, but the Weblct U2000 was not working
 



Alarm Information

None



Handling Process

To enable DCN in a E1port It is neccesary to open navigator and followt he procedurde explained below:

dcn-cfg-set-dcnifen:boardid,subcardid,portid,pathid,dcniftype,enableflag;

boardid: ;

subcardid: 1~N,invalid-0xff;

portid: 1~M;

pathid: 0;

dcniftype: ethdcnif,ethnmsif,e1dcnif,posdcnif,cstmdcnif,mwdcnif;

enableflag: enable,disable;

SAMPLE:

:dcn-cfg-set-dcnifen:1,1,1,0,ethdcnif,enable;

 

 

 



Root Cause

Huawei engineer tried to use the WebLCT U2000 to enable the DCN of one specific CXPR E1 port but WebLCT software failed to installed in the computer. The only solution without a management software as imanager or WebLCT is to use navigator.



Suggestions

  • Have Navigator always installed in the computer in order to solve problems quicker than heavy software applications
  • Have in hand always a list of basic commands to enable primary parameters of RTN