Issue Description
One day customer find that hot patch in gscc only exist ofs1 or ofs2  after he add patch;
He has a question: does he need to add hot two places?
Alarm Information
Null
Handling Process
no need handle
Root Cause
1, Check with <optix NG-SDH hot patch version upgrade guide>, you will find: load patch to ofs2 of master active gscc and load patch to osf1 of slave gscc, not say need load two OFS place
  At the same time, after we load patch to GSCC and find not two ofs exist patch files( fpatch.pat and state.pat);
  
2, Discuss with RND and know that patch exist one ofs(ofs1 or ofs2) which it is ok,no need to exist in two ofs;
   When board start, it will  patrol to find patch file and start patch by itself;
Suggestions
Check <optix ng-sdh hot patch version upgrade guide> 