No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Many BD_STATUS alarm at the RTN900 cause the 2G sites down

Publication Date:  2012-07-25 Views:  44 Downloads:  0
Issue Description
Many 2G sites flashing Lapd_alarm at M2000 and all the boards at the RTN950 reported BD_STATUS.

Alarm Information
BD_STATUS at all the boards of the RTN950.

Handling Process
We checked the power input to the RTN and we found it ok.
We checked the CSH and the boards hardware and there is no problem.
We started to check the clock quality, we found it is free running.
We started to configured it, we found there is a loop in the clock configuration which cause the clock acted as free running.
When we make the clock as per the design, all the alarms cleared and no more flashing for the 2G sites.

Root Cause
There is loop at the clock configuration.

Suggestions
After making a clear plan for the clock, and start to submit it all at one time, it will not be reflecting any conflict or loop, have to check the clock loop carefully by engineer.

END