SSN2EFS4 board shows huge traffic in DISABLED physical port due to it is logically added as N1EFS4

Publication Date:  2012-07-25 Views:  33 Downloads:  0
Issue Description
SSN2EFS4 is logically configured as N1EFS4 by Customer. The board shows huge receive/trnsmit traffic on DISABLED and not connected to any client equipment  physical port when check RMON performances.
Alarm Information
None
Handling Process
1. Delete services on the board
2. Delete the board logically
3. Newly add SSN2EFS4 as N2EFS4 board, not as N1EFS4.
4. Check RMON performance statistic for disabled ports. It must be zero.



Root Cause
Inconsistent between physical and logical board.
Suggestions
null

END