FAQ - How to Configure Basics Paramenters for the Microwave Link by Navigator

Publication Date:  2012-07-25 Views:  52 Downloads:  0
Issue Description

In RTN910V1R1 Huawei engineer needed to configure parameters for the upload microwave link Tx Frequency, add board physical, setting bandwith and modulation type , because RTN doesn´t have any configuration, and the Weblct U2000 was not working.


Alarm Information
None

Handling Process

1. Command for the to verifiy wich boards installed physical in the RTN.
:cfg-get-phybd
2. Command for the to verify wich bords logical reconize in the RTN.
:cfg-get-board
3. Command for the installed board in the RTN.
:cfg-add-board:24,tnd1odu
4. Command for the setting frequency in the RTN.
:radio-cfg-get-odu-txfreq:23,0xFF
:radio-cfg-set-odu-txfreq:23,0xFF,7177000;
5. Command for the setting power Tx in the RTN.
:radio-cfg-set-odu-tsl
:radio-cfg-set-odu-tsl:23,0xFF,200;
6. Command for the setting IF Channel Bandwith in the RTN.
:radio-cfg-get-if-bandwidth:3,0xFF,0
:radio-cfg-set-if-bandwidth:3,0xFF,1,4;
7. Command for the setting link ID in the RTN.
:radio-cfg-get-linkid:3,0xFF,1
8. Command for the to verifiy tipe of modulation in the link.
:radio-cfg-set-if-currmod

Please refer the attachment for the details of the command running result and command parameter information.


Root Cause

Huawei engineer tried to use the WebLCT U2000 to basics configuration Tx frequency add boards physical, seting bandwith and seeting modulation , but WebLCT software failed to installed in the computer. The only solution without a management software as imanager or WebLCT is to use navigator.


Suggestions
  • Have Navigator always installed in the computer in order to solve problems faster than heavy software applications.
  • Have a list of basic commands to enable primary parameters of RTN in hand always.
  • We don't recommend to use navigator in order to configure RTN, in this cases, the Weblct don’t work, this tool is necessary.
.

END