No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-Why the number of MAC address table is different on different LPU when use VPLS

Publication Date:  2012-07-27 Views:  4 Downloads:  0
Issue Description
Q: For VPLS network, when Router learned MAC address, it will synchronize to all of LPU, but why the number of MAC address table is not consistent for different LPU?
Alarm Information
NULL
Handling Process
NULL
Root Cause
A: for NE40E&80E implementation, it will judge the outbound interface of this packet which router learned source MAC address. The different type of outbound interface has different process.
Outbound interface is PW side: MAC address will synchronize to all of LPU
Outbound interface is AC side, but is Eth-trunk port: MAC address will synchronize to all of LPU
Outbound interface is AC side, but is physical port: MAC adderss will just only learn on the downstream LPU which has outbound port
Suggestions
NULL

END