No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

R_SLIP alarm due to board is moved

Publication Date:  2012-07-25 Views:  52 Downloads:  0
Issue Description
One day ,engineer report there is R_SLIP alarm rise in a 1600G .
Its version is v1r5
Alarm Information
R_SLIP
Handling Process
1.There is not other alarm
2.ST2 board was moved to other slot
3. Change the clock tracing to the new slot of st2 ,alarm disappear
Root Cause
The st2 board was moved to another slot but configuration of time trace is not changed .
Suggestions
There is still clock tracing configuration in 1600G .So ,its configuration should be checked when the R_slip and T_slip alarm rise .

END