FAQ-What's the differences between V1R6 and V6R2 ME60's air filter alarm and mechanism

Publication Date:  2012-07-27 Views:  72 Downloads:  0
Issue Description
Q:
What's the differences between V1R6 and V6R2 ME60's air filter alarm and mechanism?

Alarm Information
null

Handling Process
A:
let's take V1R6C05SPC600 and V6R2C02SPC100 as examples and compare these two versions, the differences are as below:

1. if the alarm is caused by the air filter is not cleaned periodically, the clean cycle(interval time between two times of cleaning) between these two versions are different.

for V1R6, the cycle is 180 days:
display dustproof
Clean Dustproof-Net cycle : 180(days) //cleaning cycle
Last clean date : 0000/00/00 //last date of the cleaning
Up to last clean days : 191(days) //how many days gone by since the last cleaning
Clean alarm existence days: 11(days) //how many days the air filter alarm has been existing

for V6R2, the cycle is 90 days:
dis dustproof
Clean Dustproof-Net cycle : 90(days)
Last clean date : 0000/00/00
Up to last clean days : 128(days)
Clean alarm existence days: 38(days)

2. the alarm shows differently between these two versions:

for V1R6:
dis alarm all
----------------------------------------------------------------------------
Level Date Time Info
Error 10-09-19 01:54:04 The air filter is failed, perhaps Maybe it is not cleaned as scheduled. Please clean it and run the reset dustproof run-time command.
----------------------------------------------------------------------------

for V6R2:
dis alarm all
----------------------------------------------------------------------------
Index Level Date Time Info
1 Critical 12-01-02 04:13:14 The air filter inside the chassis was not cleaned.[CHASSIS 1]
----------------------------------------------------------------------------


Root Cause
null

Suggestions
if the alarm is caused by the air filter is not cleaned periodically, after cleaning the air filter, customer should execute the below command to reset the time counting start from 0 again:

<ME60>reset dustproof run-time

END