Can't select ODU2-1 on TN54NS3 if some other already created due to U2000 problem

Publication Date:  2012-07-25 Views:  9 Downloads:  0
Issue Description
Phenomena appear during cross-connect creation by U2000 for TN54NS3 board.
If any ODU2 level cross-connection with number ODU2-2 or ODU2-3 or ODU2-4 is created. We can't create cross-connection ODU2-1 in grafic mode. We have no possibility select ODU2-1 in grafic mode. U2000 version is U2000V100R002C01SPC100.
Alarm Information
Have no any alarm. You just have no possibility select ODU2-1 in grafic mode.
Handling Process
We can't create ODU2-1 on TN54NS3 if some other already created. We have no possibility select ODU2-1 in grafic mode. We tryed to create service by another way. If we will use Create Cross-Connection Service and set ODU2-1 manually, service will be created successfully. So it is not TN54NS3 board limitation. It is problem with U2000 displaying. Related information is in attachment.
We asked R&D and received answer that problem will solve at U2000V100R002C01SPC502.
Root Cause
We can't create ODU2-1 on TN54NS3 if some other already created. We have no possibility select ODU2-1 in grafic mode. But if we will use Create Cross-Connection Service and set ODU2-1 manually, service will be created successfully. So it is not TN54NS3 board limitation. It is problem with U2000 displaying. Related information is in attachment.

Suggestions
Upgrade to U2000V100R002C01SPC502.

END