Login Anomaly of User Master to the N8000 Engine

Publication Date:  2012-07-18 Views:  52 Downloads:  0
Issue Description
In an N8000 office, after the system is installed on the NAS engine server, the user cannot log in to the console as user master on the ISM. However, user support can use the su - master command to switch to user master, or you can log in as user master using KVM.
Alarm Information
None
Handling Process
Locate the /etc/security/access.conf file on each node of the NAS cluster, and comment the last two lines with #.
##+:support:All
##-:master:All EXCEPT LOCAL
The fault is rectified.
Root Cause
Check the /etc/security/access.conf login configuration file. It is found that the last two lines shield the remote login function of user master.
+:support:All
-:master:All EXCEPT LOCAL
Suggestions
The engine server of the N8000 comes preinstalled with the operating system and NAS system software. However, certain configurations requires modifying.