Alarm Indicator is Still Red on After the Fault on the S5300 Storage System is Rectified

Publication Date:  2012-07-18 Views:  52 Downloads:  0
Issue Description
On a deployment site, a fault on the S5300 storage system is rectified. The S5300 runs properly. After the status of the S5300 is manually restored on the Web page, the alarm indicator is still red on.
Alarm Information
None
Handling Process
Enter the MML mode and run the dev sesstartlight 0 command to turn off the alarm indicator of the controller enclosure. Note: Execute the command on both controllers.
Root Cause
Although the status of the S5300 is manually restored on the Web page, this restoration command does not take effect on the bottom layer of the storage system.
Suggestions
None