S2600 System Hang Problem

Publication Date:  2012-07-20 Views:  35 Downloads:  0
Issue Description
S2600 system hang and dead in using and system can’t be accessed by CLI nor GUI.
Alarm Information
None
Handling Process
temporary solution: restart system and check whether problem solved
permanent solution: change power module
Root Cause
S2600 power module has compatible problem with backboard firmware, which cause this problem come out at times.
Suggestions
None

END