All Disks in the S5100 Storage Device Encounter a Transient Break for 10 Seconds when a Faulty Disk is being Replaced

Publication Date:  2012-07-20 Views:  77 Downloads:  0
Issue Description
When a faulty disk in the S5100 is removed, the status indicators of all disks are off for 10 seconds.
When a new disk is being inserted in the S5100, the status indicators of all disks are off for 10 seconds
Alarm Information
None
Handling Process
It is a normal phenomena, which does not affect the upper-layer services. No operation is required.
Root Cause
When a disk is being removed or inserted, the SAS link rediscovers the disk. The rediscovery process takes 10 seconds.
Message mpt-unjam is displayed.
 
Suggestions
It is a normal phenomena that all disks encounter a transient break for 10 seconds when a disk is being inserted or removed. It is unnecessary for the onsite staffs to worry about it.