Can the Single-machine Network be Used to Manage the PSM when the Multi-machine Network is Faulty?

Publication Date:  2012-07-23 Views:  35 Downloads:  0
Issue Description
Can the single-machine network be used to manage the PSM when the multi-machine network is faulty?
 
Alarm Information
None.
Handling Process
When the multi-machine network is faulty, you can use the single-machine network to manage the PSM. However, you can only view the recording policies and linkage policies but not set them. If you want to use the single-machine network with full functions, you need to log in to the V1300N to set the working mode to single-machine as follows:
Step 1  Log in to the PSM command line interface and stop the PSM service.
V1300:/hinvs/scripts # service iNVS stop
Step 2  Run the mode switchover script to set the working mode to single-machine.
V1300:/hinvs/scripts # cd /hinvs/tools/Switch
V1300:/hinvs/tools/Switch # ./Switch.sh on
Enter Y for the confirmation followed.
Step 3  Start the PSM service.
V1300:/hinvs/scripts # service iNVS start
 
Root Cause
None.
Suggestions
None.

END