Introduction to the USG5300 USB Automatic Upgrade Files

Publication Date:  2012-07-23 Views:  35 Downloads:  0
Issue Description
The USG5300 V100R003 has a new function, the USB automatic upgrade function. This case introduces the files required by the upgrade.
Alarm Information

None.

Handling Process
Use the text tool to edit the following content in the upgrade file:
[UPGRADE INFO]: indicates the upgrade information.
OPTION=AUTO: The value AUTO indicates that automatic upgrading is enabled, while the value MANU indicates that automatic upgrading is disabled.
FILENUM=2: indicates the number of description modules used by the system for upgrade file resolution. The value is 1 or 2.
[FILE DESCRIPTION]
OPTION=OK: indicates whether an upgrade is needed. The value OK indicates that an upgrade is needed. The value NOK indicates that an upgrade is not needed.
TYPE=SYSTEM-SOFTWAR: indicates the upgrade file type. The value SYSTEM-SOFTWARE indicates the system software. The value SYSTEM-CONFIG indicates a configuration file.
DIRECTORY=DEFAULT: indicates the upgrade file directory. The value DEFAULT indicates that the upgrade file directory is the root directory. The value file indicates that the upgrade file directory is udisk0:/file.
FILENAME=sup.bin: indicates the name of the file to be upgraded without the path.
[FILE DESCRIPTION]
OPTION=OK: same as previous.
TYPE=SYSTEM-CONFIG 
DIRECTORY=DEFAULT
FILENAME=vrpcfg.zip
Root Cause
  1. The autoupgrade.ini upgrade file, which is necessary for an automatic upgrade. 
  2. The system file, a file whose file extension is .bin.
  3. The configuration file, a file whose file extension is .cfg or .zip.
Suggestions
None.

END