No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Low dialing rate in a associated research conference in some ISDN bureau

Publication Date:  2012-09-19 Views:  20 Downloads:  0
Issue Description
In some bureau, there are about 25 terminals, with most of them are out of the local province, being connected with the ISDN network. The MCU and each terminal can be connected in normal debugging. But when there is a associated research conference, the dialing rate of other council houses is so low and can’t join the conference after the first ten council houses join the conference.
Alarm Information
Each terminal dial the MCU and get such information “no circuit or path available”, “no information unit content/format available”
Handling Process
Sent this problem to the telecom, then the telecom expands the path source after analyzing the problem. When the next associated research conference is held, the problem is solved.
Root Cause
With the ISDN network, suppose each terminal corresponds with 6 B channels. When there is a conference, if there are 25 council houses, we need 180 B channels, however, the number of digital path between telecom long-distance bureau and MCU is limited, and it can’t meet the demand of path source in a associated research conference. After the bureau expands the path source, the problem is solved.
Suggestions
none