Resolving of CLI terminal and Huawei8620 can’t interact

Publication Date:  2012-09-22 Views:  43 Downloads:  0
Issue Description
Certain bureau former network has CLI equipment, now they want to connect CLI equipments to our company’s 8620 switch platform, but when 8620 convene an conference, the CLI terminal can’t join the conference normally.
Alarm Information
Capability set mismatch
Handling Process
1.because CLI equipments have been used for a very long time, the maintainer of bureau side have been replaced many times. They don’t know configuration of CLI.
2. Base on fact, change parameter on 8620 to match the capability of bureau.
3. Change video, audio configuration parameter, but the change has no effect.
4. The problem may be on data channel, shut down low speed rate channel, CLI can join the conference normally. Problem solved.
Root Cause
Terminal capability configuration and 8620 capability configuration mistch
Suggestions
None