No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Camera can’ be normally controlled

Publication Date:  2012-09-22 Views:  94 Downloads:  0
Issue Description
Bureau maintainer find out that when they operate camera to move up, down, left, right, camera can’t move short distance, it can only to the edge of each direction.
Alarm Information
None
Handling Process
Analyze the phenomenon, the reason may be:
1. Terminal data configuration fault.
2. Camera has malfunction
3. Connection  of terminal host and camera has malfunction
4. Terminal host has malfunction
Set the video control data on operation platform again, restart host, the problem is not solved. Eliminate the first possibility; replace another normal camera, control is still abnormal; eliminate the second possibility; check the camera and terminal’s connection, plug and unplug the line, control is still abnormal, eliminate the third possibility; replace host, set the data, camera control becomes normal, problem is solved
Root Cause
Because of the bad welding, there may be soldering tin left on circuit board, or dry joint on internal circuit. When using, a slight shock may cause circuit malfunction. Then control signal can’t transmit normally.

Suggestions
None

END