FAQ-How to configure the RAID of T3500?

Publication Date:  2012-09-25 Views:  33 Downloads:  0
Issue Description
No RAID has been installed in T3500 before in some bureau, and we must install and configure the RAID in field. This example has introduced the steps of inputting configuration information in the installation of the RAID in T3500.
Alarm Information
NA
Handling Process
1. Get the latest ipmi tool package including some inputting script for upgrading and some executing files. Copy it to the root directory in C:\.
2. Begin-->run-->cmd, enter dos, then enter the ipmitool interface.
3. Input up, press Tab, it comes to command upgrade.dat automatically. Input the management IP address, press enter.
4. Press 4 and input the password t3000diag later.
5. Input zone 2. Pay attention that “zone 2” is invisible.
6. Input reset for rebooting T3500.
7. Power off and on the T3500, and the configuration is finished.
Root Cause
For the information of the extended board of T3500 and RAID doesn’t match, the RAID doesn’t work. We should modify the configuration information of the RAID.
Suggestions
It is recommended that we should not install RAID in field instead of the factory, for the installation in field is complex including hardware installation and software debugging.