MIPU board alarms, but no prompt in local management desk.

Publication Date:  2012-09-27 Views:  43 Downloads:  0
Issue Description
One MIPU board condition is alarm checking in local management desk but no any alarm information. Check MCU resource by RMCC, no resource belongs to this MIPU. In local management desk, we can see that this MIPU board indicator is green. 
Alarm Information
This board condition is “alarm” showing in local management desk.
Handling Process
Pulling out and plugging board do not have any effect. Change board slot and everything is normal, which means board is good. So it is motherboard interface behind slot that has problem. So we should change slot. 
Root Cause
Data configuration problem causes interface connection problem and board problem, but local management desk has no prompt.
Suggestions
It does not means normal that no yellow or red board MCU in local management desk. We should check every board regularly.