Time amending method of cyclic conference

Publication Date:  2012-09-28 Views:  52 Downloads:  0
Issue Description
Because operate permanent conference on Train 5.2, MCU can’t reset for a long time and suspend, cyclic conference can fix this problem
Alarm Information
None
Handling Process
In config.xml, the conference end time of calling meeting place doesn’t join the conference is:
<Param>
      <ID>7008</ID>    
      <Name>CallSite_WaitTime</Name>
      <Type>Integer</Type>
      <Default>600</Default>
      <INI>.\\rmcc.ini</INI>     
      <Session>SYS</Session>
      <Use></Use>
    </Param> 
the setting of no meeting place join the conference and end the conference is :
    <Param>
      <ID>7009</ID>    
      <Name>AllSite_WaitTime</Name>
      <Type>Integer</Type>
      <Default>1200</Default>
      <INI>.\\rmcc.ini</INI>     
      <Session>SYS</Session>
      <Use></Use>
    </Param>
        The unit of these two options is second
Please copy these two options to [sys] segment of RMCC.ini file.
For example: If calling meeting place doesn’t join the conference for3 minutes or no meeting places join the conference for 20 minutes, the conference will finish itself.
CallSite_WaitTime=600
AllSite_WaitTime=1200
After setting, restart RM service.
Add the following two pieces to RMCC.ini, after setting, restart RM service.
Specific operation step is as follows:
[SYS]
; suggest setting the following meeting places and charge period to the same integer.
;conference charge period(second)-Conf_Fee_Interval(5~1800)
Conf_Fee_Interval=300
; conference charge period(second)-Site_Fee_Interval(5~1800)
Site_Fee_Interval=300
;Session Timeout - (charge overtime: greater than 120 seconds && greater than 2 times of conference period)
AccountSessionTimeout=600
;conference special service number-Special_Conf_Code(1~12 byte number)
Special_Conf_Code=168
;whether send conference information to GKM (1:send,0:do not send)
GKM_Endpoint_Enable=1
;charge system type that hanging in the system-(1: vBill;2: iTellin)
Sys_Bill_Server=1
;MCU resources type of PSTN conference meeting place that can be assigned (1:PRI;2:VoIP)
MCU_Type_Of_PSTN=2
;4 frame mode-(1: standard 2: nonstandard H.263 3: nonstandard H.264)
MultiPic4_ParamType=1
;conference remain time display(minute)(1~10 minutes)
Conf_RemainTime_Show=1
;whether check the validity of conference number
Enable_Check_Site=0
;free charge time of conference(minute)
Free_Charge_Time=0
;cyclic conference budget deduct time (0:no deduct,1:by week,2:by month)
PeriodicConf_Budget_Interval=1
;permanent conference budget deduct(0:no deduct,1:by week,2:by month)
PermanentConf_Budget_Interval=2
;whether cancel cyclic conference when system fail to operate the conference (0:don’t cancel,1:cancel)
Cancel_All_PeriodicConf=1
;restart conference interval when none RMCC conference finish permanent conference.(minute) PermanentConf_Restart_Interval=3
CallSite_WaitTime=600(600 change to real time)
AllSite_WaitTime=1200(600 change to real time)
Root Cause
Because operate permanent conference on Train 5.2, MCU can’t reset for a long time and suspend, cyclic conference can fix this problem
Suggestions
Thank the guidance of teacher Ma, teacher Lu and teacher Liu.