No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-how to solve the problem on array that host type of VIS is wrong and it cannot find disk after configuring rightly

Publication Date:  2012-10-10 Views:  49 Downloads:  0
Issue Description
Set wrong VIS type of host on array, VIS cannot find disk, but after modifying it to Linux, VIS can still not find disk.
Alarm Information
none
Handling Process
1. Make sure host type of VIS on array is linux.
2. Cut the cable of VIS array, scan disk on VIS and then VIS will delete the wrong information.
3. Insert the cable, scan disk on VIS, then you will find the right disk.
Root Cause
After scanning disk on VIS, it keep wrong disk information on VIS. Modifying type on array cannot update the wrong information.
Suggestions
none

END