Publication Date:  2012-10-10 Views:  39 Downloads:  0
Issue Description
After reboot, system says the battery of RAID card is error or out of position when self-check.
Alarm Information
none
Handling Process
If the deivice is VTL3500, press ‘D’ to shut the alarm, because there is no battery in VTL3500. If the device needs battery, operate as follow:
1. When initializing press ‘CTRL+H’ to enter configuration UI, click ‘Controller Properties’. Check the battery position state. ‘Present’ is on position, ‘NONE’ is out of position.
2. If it is ‘NONE’, open the shelf and examine if the battery is linked to the shelf, if the cable is broken, if the link between cable and battery is normal.
3. If everything above is OK, replace it by a new battery.
4. If the battery is on position, make sure the server is open for more than 30 minutes, at this time, the battery will be charged.
Root Cause
This is a alarm information, it says there is no battery, maybe the battery is error, or is cut down. If the system don’t need a battery, please press ‘D’ to shut the alarm, the alarm is proleptic.
Suggestions
none