No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

The solution of deduplication cannot be performed after the device powering off abnormally

Publication Date:  2012-10-11 Views:  48 Downloads:  0
Issue Description
1. Establish typical network configuration 4. SIR is related to vlt-B, and two backup server are both related to vtl-B. Establish a VTL on vtl-B.
2. After configuring, vtl server, vtl software and vtl service are running well.
3. There is deduplication work on vtl-B.
4. First close engine power of SIR.
5. Then close engine power of vtl-B.
6. Last close engine power of the two S2600.
7. After finishing deduplication, first start S2600, then start vtl engine, last start sir engine.
8. After powering on, the deduplication cannot work. But type ‘sir status’ in SSH, all the sir servers are running.
Alarm Information
none
Handling Process
1. Make sure the LUN resource is scanned.
2. The deduplication is good after reboot.
Root Cause
Although SIR boots normally, some service don’t start normally.
Suggestions
none

END