No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Choose the right link mode when VTL linking host and storage, or VTL cannot find storage, host cannot find VTL

Publication Date:  2012-10-11 Views:  16 Downloads:  0
Issue Description
Link storage and HDD cage, then VTL HDD cage cannot find the storage.
Alarm Information
none
Handling Process
There are two kinds of FC port mode in VTL: p2p and loop. When link by switch, modify the mode to p2p, or to loop.
1. # vi /usr/local/vtl/etc/fshba.conf
2. Modify “connection_option-hba” to “1”. 1 stands for p2p, 0 is for loop.
3. :wq !  (save and exit)
4. Restart VTL server
Root Cause
Storage and HDD cage can link directly or by switch. Direct link’s mode is loop, while link by switch mode is p2p.
Suggestions
none

END