Maintenance terminal connect VTL3500 through IPMI port, but cannot log on MegeRAID client

Publication Date:  2012-10-15 Views:  36 Downloads:  0
Issue Description
When deployment, connect VTL3500 to maintenance terminal through IPMI port. Input IP address in MegeRAID client and click update button, there is no reaction and cannot connect VTL.
Alarm Information
Na
Handling Process
Connect VTL3500 to maintenance terminal with NIC1 network port, log on MegeRAID client normally to configure.
Root Cause
There are three network ports in VTL3500: PIMI, NIC1, NIC2, IPMI is management network port. Default IP is 192.168.11.2, it support access to VTL3500 with ISM interface;
When access and configure VTL3500 with MegaRAID client and VTL Console, it cannot use IPMI network port, and can only use NIC1, default IP address is 192.168.11.1.

Suggestions
Maintenance terminal log on MegaRAID and VTL console to configure VTL3500 through NIC1 network port, and log on ISM and do configure through IPMI network port. 

END