[VTL6000] VTL software fault: we can’t create mirror for database after configuring Failover

Publication Date:  2012-10-15 Views:  15 Downloads:  0
Issue Description
After configuring Failover we can distribute storage LUN, then delete the original database mirror, add the new database mirror, it warns error.
The phenomenon is as below:
In VTL console navigation, click “VTL server”, choose “event log label” in the right operating area, examine the event message, it shows there has been mirror database and can’t add the new database mirror.
Alarm Information
na
Handling Process
1. In VTL console navigation, right-click “physical resource” and choose “scan over again”.
2. Choose “find the new device” in the “appoint the adapter, SCSI ID and LUN area which need to scan” dialog box, then appoint the area of “SCSI ID”.
We advise the SCSI ID is 128.
3. Click “confirm”, begin to scan.
4. In VTL console navigation, choose “visual tape library system”, right-click “database” and choose “mirror>add”.
5. Choose the physical devices which need to add mirror in the “create visual tape library database mirror” dialog box.
6. Click “finish”.
Root Cause
There can be only one database mirror in VTL. If we delete the original database mirror, VTL console software hasn’t update in time, so it warns that we can’t add the new database mirror.
Suggestions
na