RH2285 new replaced hard disk cannot be added into RAID group and red light brighten

Publication Date:  2012-10-19 Views:  39 Downloads:  0
Issue Description
A customer site, new hard disk is replaced, red light brighten, and cannot be added into RAID group.
Alarm Information
None
Handling Process
Method 1:
No data in field, so directly delete RAID group;
Concrete step is like:
1. Select RAID card property

2. check existing RAID group

3. manage RAID group

4. delete RAID group

Method 2:
If there is data in field, change new replaced hard disk into hot spare disk, initialize automatically, and synchronize data after initialization finish.
1.  three steps ahead is same as method 1, the fourth step is: select manage hot spares.

2. press SPACE and select YES, save and quit.


Root Cause
New applied hard disk has RAID card (1068E) configuration information and cannot be added into RAID group.
Suggestions

As some hard disk RAID information is not complete clear, we must clean the information manually.