TSM product V100R002C01SPC001 version import testing license failure

Publication Date:  2012-10-19 Views:  58 Downloads:  0
Issue Description
A site pre-sale testing needs to apply for non-commercial license of PSM and TSM, after applied import it to PSM successfully, but it prompts license illegal.
Alarm Information
None.
Handling Process
Download Secospace TSM V100R002C01SPC200, according to the instruction to upgrade and re-import testing License.
Root Cause
Through viewing the TSM version is: V100R002C01SPC001, and the building date is: Jan 30th, 2010
Through consulting from research and development we know that when V100R002C01SPC001 this version released the HuaweiSymentec license platform didn’t exist, so this version does not support HuaweiSymentec’s license, need to use huawei's license. Or upgrade to version V100R002C01SPC200 can solve License illegal problem.
At that time the applied License is applied by HuaweiSymentec’s notes, so the test License will prompts illegal error.
Suggestions
When seek help from research and development, needs to feedback the scene version and the error information to research and development in time.