No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration problem leads S9306 device G24CA board electrical interface is not through

Publication Date:  2012-10-19 Views:  53 Downloads:  0
Issue Description
S9306 device G24CA board electrical interface cannot up.
Alarm Information
NULL
Handling Process
Configure in corresponding physics view: combo copper, set corresponding interface as electrical interface, failure remains.
Configure in corresponding physics view: mdi across, identify across reticle, the problem is solved.
Root Cause
G24C board has 8 electrical ports and 24 optical ports, front 8 optical ports is multiplexing with electrical ports, it need to configure by combo command, it select fiber interface by default.
Suggestions
Electrical board of S9306 has combo and mdi 2 key points, it should consider 2 key points when problem appears, it cannot solve the scene problem when it consider the single factor.

END