FAQ-What is notice matters for configuration fo RRPP

Publication Date:  2012-10-31 Views:  43 Downloads:  0
Issue Description
Q:
What is notice matters for configuration fo RRPP
Alarm Information
NULL
Handling Process
The notice matters for configuration fo RRPP:
1. Because the hardware standard limit, 24 ports and 48 ports interface board have mostly 96 and 144 rules for rrpp using, so it should distribute the resource with reason when muti RRPP circle topology, it cannot configure by random.
2. S9300 does not support RRPP and MSTP intersect topology, because all the ports of RRPP circle shoud enable STP.
3. Network convergence speed related with configuration domain, the circle number, convergence speed will be faster when the configuration mumber lower.
Root Cause
NULL
Suggestions
NULL