How to make data synchronization to the OMS Portal after adding the switches in the MN Portal

Publication Date:  2012-11-13 Views:  49 Downloads:  0
Issue Description
Q:
In the version of R002C00SPC200, we add switches in the MN Portal successfully, but there hasn’t refreshed in the OMS Portal and can’t see the new added switches.
How to synchronize the new added data in the MN to the OMS?

Alarm Information
None
Handling Process
A:
1. After adding switches in the MN Portal, we need to login in the MN via PUTTY and execute the command “captest refreshtopo”, then synchronize the configuration on the MN to the OMM node.
2. Execute command “captest refreshtopo” will cause the OMS Portal to restart and we can’t login in a moment.

Root Cause
None
Suggestions
None