Q:
Can 9300 switch backup main control board synchronizes main control board version and patch files?
Alarm Information
NULL
Handling Process
A:
According to product design,if the backup main control board has the version, it can synchronizes main control board version and patch files, it is not related with version. but the different version shychronization mechanism caused that some version fails to synchronize:
1、V1R1 as master:backup as V1R1/V1R2  can normally synchronize, backup as V1R3 cannot synchronize,backup as V1R6 cannot synchronize,sph021 patch,after add the patch,backup as V1R6 can normally synchronize, synchronization time is 5-10 minutes,backup as V1R3 cannot synchronize;
2、V1R2 as master:backup as V1R1/V1R2 can normally synchronize,backup as V1R3 cannot synchronize,backup as V1R6 cannot synchronize,sph020 patch,after add the patch,backup as V1R6 can normally synchronize,synchronization time is 5-10 minutes,but backup as v1r3 cannot synchronize;
3、V1R3 as master:backup as V1R1/V1R2 cannot synchronize, backup as V1R6 can normally synchronize,sph011 patch,after add the patch,backup as V1R1/V1R2 can normally synchronize,synchronization time is 10 minutes;
4、V1R6 as master:backup as V1R1/V1R2 can normally synchronize,synchronization time is 10 minutes,backup as V1R3 can normally synchronize.
Root Cause
NULL
Suggestions
NULL