No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Synchronize Ethernet interface failed

Publication Date:  2012-11-21 Views:  34 Downloads:  0
Issue Description
Synchronize the properties of network element failed, prompting synchronous Ethernet interface characteristic failed. 
Alarm Information
None.
Handling Process
1. Reason 1: the Telnet/STelnet parameter configurations between network management side and network element side are not consistent.
Check whether the Telnet/STelnet parameter configurations between network management side and network element side are consistent. If not, modify the Telnet/STelnet parameter of the network management and then try again.

2. Reason 2: the number of the registered users in network element has reached the maximum limit land users, resulting in network management cannot login.
A. Execute command “display users all” to check the users has already registered.
[Eudemon]display users all
   User-Intf  Delay    Type  NetworkAddress   AuthenSta  ACF  Username
  0   CON 0                                                   Unspecified
  2   TTY 2                                                   Unspecified
354 VTY 0  01:27:41  TEL   190.120.2.102    pass       no   Unspecified
355 VTY 1  02:27:46  TEL   190.120.2.78     pass       no   Unspecified
356 VTY 2  03:19:32  TEL   190.95.2.7       pass       no   Unspecified
357 VTY 3  01:15:43  TEL   190.120.2.84     pass       no   Unspecified
358 VTY 4  00:00:00  TEL   190.120.2.69     pass       no   root
  359 VTY 5                                                   Unspecified
  360 VTY 6                                                   Unspecified
  361 VTY 7                                                   Unspecified
  362 VTY 8                                                   Unspecified
  363 VTY 9                                                   Unspecified
  364 VTY 10                                                  Unspecified
  365 VTY 11                                                  Unspecified
  366 VTY 12                                                  Unspecified
  367 VTY 13                                                  Unspecified
  368 VTY 14                                                  Unspecified
B. Check command to display whether there is spare VTY channel, if VTY channel has been occupied, please try again after forced the user offline.

3. Reason 3: the permissions of the users through the network management login network element are not enough, unable to get the current configuration of the network element, leading to synchronize failed.
A. Check the permissions of the users which through the network management login network element.
[Eudemon]display current-configuration | include root
15:20:27  2011/04/26
local-user root password simple admin
local-user root service-type telnet
local-user root level 1
Root is the name of the user which through the network management login network element.
Level 1 represents the current permission of the user is 1. In order to guarantee the operation will be successful, please configure it to level 3 or the above levels.
B. If the user permission is not enough, please improve the user level to "level 3".
[Eudemon-aaa]local-user root level 3

4. If it still can't solve the problem, please contact huawei technical support engineer.
Root Cause
Reason 1: the Telnet/STelnet parameter configurations between network management side and network element side are not consistent.
Reason 2: the number of the registered users in network element has reached the maximum limit land users, resulting in network management cannot login.
Reason 3: the permissions of the users through the network management login network element are not enough, unable to get the current configuration of the network element, leading to synchronize failed.
Suggestions
None.

END