There is no data in the flow statistics table of P2P user

Publication Date:  2012-11-29 Views:  29 Downloads:  0
Issue Description
After A customer’s SIG system completed to configure, there is no data in the P2P flow statistic table. 
Alarm Information
None.
Handling Process
Through checking, the other statements of SIG P2P module all have data, only "user flow statistics table" has no data, check the "user management" under "P2P monitoring", found can’t find any information in "the user's query", import the user information provided by customers to "users to add", and then check "user flow statistics table", found the table can generate data normally.
Root Cause
None.
Suggestions
Before carrying on the P2P user flow statistics, must add the single user or key account into the P2P users, and set the user monitor state for monitoring.