No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log server cannot collect E200 session log

Publication Date:  2012-12-14 Views:  124 Downloads:  0
Issue Description
Log server has added the E200 firewall information, but it cannot collect E200 session log
Alarm Information
NULL
Handling Process
1、Check the firewall configuration, the destination host computer, destination port and source address configuration of session log is correct
2、Check log server configuration, collection can run normally, but the collection way of elog configuration is syslog format when adding E200 firewall
3、Modify the collection way as session, the problem be solved, it can query the related session log
Root Cause
1、Firewall nat log configuration failure,that caused firewall did not send the log flow.
2、ELOG log server configuration failure
Suggestions
1、The firewall send binary numeral, it should configure the collection way as session on Elog server
2、It can by the command sending way for E1000E device(it can configure as syslog way)
firewall session log-type { syslog | binary host ip-address port }

END