Eudemon200E have Misplaced boards

Publication Date:  2013-02-16 Views:  103 Downloads:  0
Issue Description
we have a Eudemon200E  its software virsion is V100R002C00  and when we want to display the cards in it, it display one card only while there are two card had been installed in it .This is the result of the display command        
[Eudemon]display device
22:52:21  2010/12/13
Eudemon Eudemon200E-CF's Device status:
Slot #    Type        Online    Status
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0         RPU         Present   Normal
3         ADSL       Present   Misplaced
4         5FE          Present   Misplaced
8         FAN         Present   Normal
9         FAN         Present   Normal
10      PWR        Present   Normal
Alarm Information
N/A
Handling Process
According to Quidway Eudemon 200E-C&200E-F Firewall Hardware Description(V100R002_01)
The interface cards can be inserted in the slots are as follows:
- MIC 1 and MIC 2 slots
1E1, 1CE1, 1SA, 1FE, 5ESW, and ADSL2+ interface cards
- MIC 3 and MIC 4 slots
1E1, 1CE1, and 1SA interface cards
- FIC 5 and FIC 6 slots
2E1, 2CE1 and 1GE interface cards
the problem solved after changing the ADSL and 5FE boards to slots 1 and 2
Root Cause
The ADSL and 5FE boards were installed in wrong slots
Suggestions
For further assistance please contact Enterprise TAC responsible

END