GUI freezes on USG2230

Publication Date:  2013-04-23 Views:  112 Downloads:  0
Issue Description
The device needs reboot after the GUI remains into the loading screen as there is no escape command.
Alarm Information
GUI remains in loading mode
Handling Process
as handling process I backtracked the exact process that was used until the gui entered the loading screen. Whne i reached the step at which the ip address of the management interface was changed the root cause of this was obvious (as stated in previous filed = Cause Analysis)
Root Cause
When trying to change the ip address of the management interface from the gui the http session will be shutdown as the session was created with the initial ip address.
Suggestions
When configuring a device , especially for the initial configuration, use the CLI(either through telnet/ssh or console port).