FAQ: How to monitor a specific OID on eSight

Publication Date:  2013-05-26 Views:  41 Downloads:  0
Issue Description
AR1220V ------------snmp--------------- eSight server.
I will query CPU usage OID via SNMP.
R1-AR1220V>dis version
Huawei Versatile Routing Platform Software
VRP (R) software, Version 5.120 (AR1200 V200R003C00SPC200)

R1-AR1220V>dis cpu-usage
CPU Usage Stat. Cycle: 10 (Second)
CPU Usage Stat. Time : 2013-05-09  15:36:57
Control Plane
    CPU Usage:  21%  Max:  46%

Alarm Information
Step1. Find the OID.
hwEntityCpuUsage  1.3.6.1.4.1.2011.5.25.31.1.1.1.1.5

Step2. Walk the OID to see if returns the right value.
Handling Process
5. Create monitoring view for the associated performance indicator.
Root Cause
Step3.
If we have the value, we should create performance indicator using that OID leaf. You can use unspecified measuring objects, and don’t put the last “.9”. We will used later to bind it with the instance. Useful when we have multiple cpu so we can put multiple instances.

Step4.
Under Performance/Monitoring Configuration/ select your device and bind it with the configured performance indicator.After click ok, please enter Select measurement object and set as instance ‘9’ the last leaf from OID.
Suggestions
Check the view.

END