U1930(V100R001C01SPC600)call forwarding service is abnormal

Publication Date:  2013-05-29 Views:  136 Downloads:  0
Issue Description
Vietnam field uses PBX U1930,version is V100R001C01SPC600, Networking: AT0 relay and U1930. 0,1,2,slot is ASI board.Analog user extension 100 and 111 are directly connected to slot 0 ASI board through the telephone line. Outside users calls VU script,hears IVR speech,dials 0# transfering call to 100 extension.100 extension talks to outside user ok, and then 100 extension presses the flash key and 111,transfers call to extension 111,but outside the user did not hear the default waiting tone,just break.
Alarm Information
None
Handling Process
According to the fault phenomena, we can judge form the following steps:
1. first judge 100 extension has the call forwarding service or not. normally the default authority has.please use the command line to check on U1930: red means the service authority.
[%eSpace U1930(config)]#show subscriber dn 100 type newservice

New Service

Rights           Register Information
---------------- -------- -----------
NORMAL           Y
CALL_WAITING
WAKEUP_CALL
UNICALL
ABBREVIATIVEDIAL
CLIP             Y
CALLLIMIT
DDS
ABSENT_USER
CFU
CFB
CFNR
CFO
HOOKING_TRANSFER Y
AMEND_PASSWD     Y
CANCEL_ALL_NS    Y
PICKUP_IN_GROUP  Y
MULTICALLS       Y
CALLPARK
CNIP             Y

------- Matched record number : [20] -------

====  Command executed success !  ====
2.hang up the phone 100 and 111,check the state, execute the following command: we can see 100 and 111 status are normal
.
[%eSpace U1930(config)]#show subscriber asi slot 0

Subscriber

PortNo DomainName TermName Dn  LongDn SubPBXNo State BindUserNum RemarkInfo Dire
ctDialTKC
------ ---------- -------- --- ------ -------- ----- ----------- ---------- ----
---------
0      pots       POTS0    100        0        IDLE  NA                     -

1      pots       POTS1    101        0        IDLE  NA                     -

2      pots       POTS2    102        0        IDLE  NA                     -

3      pots       POTS3    153        0        IDLE  NA                     -

4      pots       POTS4    123        0        IDLE  NA                     -

5      pots       POTS5    107        0        IDLE  NA                     -

6      pots       POTS6    108        0        IDLE  NA                     -

7      pots       POTS7    109        0        IDLE  NA                     -

8      pots       POTS8    110        0        IDLE  NA                     -

9      pots       POTS9    111        0        IDLE  NA                     -

10     pots       POTS10   112        0        IDLE  NA      

3.extension 100 and 111 call to each other, when talk, please check the extension status with the same command. find that

both extensions are busy. then hang up both phones and then go back to idle status. this means wire connection and config

between U1930 and phones are right.

4.the extension 100 makes call forwarding may press "transfer" button for too long time, leading to hang up. tell the engineer to

press the button for short time and quickly for testing,but the same result.

5.check slot 0 ASI board call forwarding time limit.use command: find that no minimum and maximum time limit.
[%eSpace U1930(config)]#show hookflashtime asi slot 0

HookFlashTime

board lowerlimit upperlimit
----- ---------- ----------

====  Command executed success !  ====

6.config slot 0 ASI board for call forwarding time limit,command is as follows: you can customize time limit.
[%eSpace U1930(config)]#config hookflashtime asi slot 0 lowerlimit 30 upperlimit
1000

====  Command executed success !  ====

7.test again, call forwarding service is normal.
Root Cause
According to the fault phenomena, we can judge form the following steps:
1. first judge 100 extension has the call forwarding service or not. normally the default authority has.please use the command line to check on U1930: red means the service authority.
[%eSpace U1930(config)]#show subscriber dn 100 type newservice

New Service

Rights           Register Information
---------------- -------- -----------
NORMAL           Y
CALL_WAITING
WAKEUP_CALL
UNICALL
ABBREVIATIVEDIAL
CLIP             Y
CALLLIMIT
DDS
ABSENT_USER
CFU
CFB
CFNR
CFO
HOOKING_TRANSFER Y
AMEND_PASSWD     Y
CANCEL_ALL_NS    Y
PICKUP_IN_GROUP  Y
MULTICALLS       Y
CALLPARK
CNIP             Y

------- Matched record number : [20] -------

====  Command executed success !  ====
2.hang up the phone 100 and 111,check the state, execute the following command: we can see 100 and 111 status are normal
.
[%eSpace U1930(config)]#show subscriber asi slot 0

Subscriber

PortNo DomainName TermName Dn  LongDn SubPBXNo State BindUserNum RemarkInfo Dire
ctDialTKC
------ ---------- -------- --- ------ -------- ----- ----------- ---------- ----
---------
0      pots       POTS0    100        0        IDLE  NA                     -

1      pots       POTS1    101        0        IDLE  NA                     -

2      pots       POTS2    102        0        IDLE  NA                     -

3      pots       POTS3    153        0        IDLE  NA                     -

4      pots       POTS4    123        0        IDLE  NA                     -

5      pots       POTS5    107        0        IDLE  NA                     -

6      pots       POTS6    108        0        IDLE  NA                     -

7      pots       POTS7    109        0        IDLE  NA                     -

8      pots       POTS8    110        0        IDLE  NA                     -

9      pots       POTS9    111        0        IDLE  NA                     -

10     pots       POTS10   112        0        IDLE  NA       

3.extension 100 and 111 call to each other, when talk, please check the extension status with the same command. find that

both extensions are busy. then hang up both phones and then go back to idle status. this means wire connection and config

between U1930 and phones are right.

4.the extension 100 makes call forwarding may press "transfer" button for too long time, leading to hang up. tell the engineer to

press the button for short time and quickly for testing,but the same result.

5.check slot 0 ASI board call forwarding time limit.use command: find that no minimum and maximum time limit.
[%eSpace U1930(config)]#show hookflashtime asi slot 0

HookFlashTime

board lowerlimit upperlimit
----- ---------- ----------

====  Command executed success !  ====

6.config slot 0 ASI board for call forwarding time limit,command is as follows: you can customize time limit.
[%eSpace U1930(config)]#config hookflashtime asi slot 0 lowerlimit 30 upperlimit
1000

====  Command executed success !  ====

7.test again, call forwarding service is normal.
Suggestions
 ASI  board should have the call forwarding time limit by default. generally document does not mention, if missing, need to add it.

END