how to load the patch into MRS board in Softco9500

Publication Date:  2013-06-18 Views:  29 Downloads:  0
Issue Description
Version Information:
Softco9500 V100R002C04SPC600

Alarm Information
None
Handling Process
Here I will introduce the second method in detail:

1. connect to the MCU/SMCU board by telnet:
     [.login    .] Login:>admin
     [.password .] Password:>

     [.result   .] succeed
     [%Softco9500]>en
     [.password .] Password:>

     [.result   .] succeed
     [%Softco9500 (config)]#

2. execute the command "show board" to check the slot number of MRS board. For example, its slot number is "7";

3. execute the command "telnet 168.168.0.17" to jump to MRS board:
    [%Softco9500 (config)]#telnet 168.168.0.17
    
    after that, it will display the following warning, please input the username and password again, normally this should be admin/huawei
   
    [.login    .] Login:>admin
    [.password .] Password:>

    [.result   .] succeed
    [%Softco9500 MRS]>en
    [.password .] Password:>

    [.result   .] succeed
    [%Softco9500 MRS(config)]#   

4. Then you can load the patch. the instance commands are:
      [%SoftCo9500(config)]#Config patch load filename mrs_patch.pat
      [%SoftCo9500(config)]#Config patch active no
      [%SoftCo9500(config)]#Config patch save

5. you can check patch loading result by command: "show patch information"


Root Cause
Because the patches want to load is about MRS board, and need to load into this.
Usually we just need to connect to MCU/SMCU board when upgrade, but here we need to connect to MRS board.

There are two methods to connect to MRS board:

1) connect to the COM port of MRS board directly;

2) telnet to MCU/SMCU board, and then jump to MRS board by telnet.
Suggestions
None

END