Fault Leds Blinking Yellow

Publication Date:  2013-06-25 Views:  64 Downloads:  0
Issue Description
2 Disks in the RH2285 Server have the fault LEDs Blinking Yellow
Alarm Information
RAID Group Rebuilding 
Handling Process
After RAID rebuild process is finished the LEDs will be off normally , no action is needed to be done 
Root Cause
Due to power ourtage some data corruption happened for a RAID6 Group
For RAID6 we have 2 disks used for parity check
after power failure RAID need to rebuild itself 
While rebuilding the Fault LEDs of parity disk will be blinking yellow 
Suggestions
None

END