Errors in NBI log on EMS

Publication Date:  2013-06-27 Views:  91 Downloads:  0
Issue Description

On the eSpace EMS SPC500 the following errors occurred in the nbi.log and must check what is the root cause.


2013-06-12 15:20:00,049 ERROR [T=169][com.huawei.oms.nbi.snmpadaptor.ds.frame.service.SNMPCoreFrame.setEngineBoots() 638] FileStream Close failed :java.io.IOException: Bad file descriptor

2013-06-12 15:20:00,133 ERROR [T=62][com.huawei.oms.nbi.utility.ds.config.UtilityConfigReader.addFTPUsers() 297] AddUser Failed:name is empty

Alarm Information
None.
Handling Process
1. Make sure all services are running
2. Double check with R&D
Root Cause
1. Check running status of the EMS
2. Check SNMP on EMS and on the upper NMS
3. Capture packets on the EMS to the upper NMS for SNMP packets
4. Check the following in the nbi.xml file:
• SNMP settings under <UserSnmpInfo>
• FTP user under  <CommonFTPInfo>
Suggestions
Conclusion: These errors in the nbi.log do not affect the services and can be ignored.

For the first error, it’s due to the program code close the “FileOutputStream” first and then close the “ObjectOutputStream”.

For the second, the error is due to the fact that ftp user if configured. FTP service is not a must for the main operation services of EMS.