EMS NBI is not supporting multiple superior NMSs

Publication Date:  2013-07-22 Views:  95 Downloads:  0
Issue Description
when configure 2 different nms ,the second nms is down ,but the first one is ok
Alarm Information
connect error .
Handling Process
Check the configuration of NBI.XML ,found that the the value of commstring of the 2nms is same .
change the second one with a password of nms ,and must be encrypt by the tool
Root Cause
when configure multi NMS, the OSSId ,CommString must be different .
Suggestions
when configure multi NMS, the OSSId ,CommString must be different .
OSSID is the ip address ,commstring is the password of nms ,and should be encrypt by the tool which can be found in the version package .